Follow us :

6kA JVL15-63 factory direct sales high quality 6.2kV 16 mcb circuit breaker

6kA JVL15-63 factory direct sales high quality 6.2kV 16 mcb circuit breaker
6kA JVL15-63 factory direct sales high quality 6.2kV 16 mcb circuit breaker6kA JVL15-63 factory direct sales high quality 6.2kV 16 mcb circuit breaker6kA JVL15-63 factory direct sales high quality 6.2kV 16 mcb circuit breaker
group name
Economic 4.5KA, 6kA Regular Series Circuit Breaker
Min Order
1 piece
Delivery clauses under the trade mode
FOB, CFR, EXW
Acceptable payment methods
T/T, L/C, Credit Card, PayPal, Westem Union, Cash
update time
Fri, 05 Jul 2019 15:55:23 GMT

Paramtents

  • Mode electro- magnetic type , electronic type

  • Residual urrent charateristis A, AC

  • Pole No 2, 4

  • Rated current(A) 16, 25, 40, 63

  • Rated voltage AC 230/400V

  • Rated frequency 50/60Hz

  • Terminal Connection Height 21mm

  • Electro-mechanical endurance 4000 cycles

  • Fastening torque 2.0N.m

  • Protection class IP20

Packging & Delivery

  • Min Order1 piece

Briefing

Automatically disconnect the circuit when earth fault/leakage current occurs andexceeds the rated sensitivity.

Detailed

Technical Data 

Mode: electro-magnetic type, electronic type

Residual current characteristics: A, AC

Pole No.: 2, 4

Rated making and breaking capacity: 500A(In=25A,32A,40A) or 630A(In=63A)

Rated current(A): 16, 25, 40, 63

Rated voltage:  AC 230/400V

Rated frequency: 50/60Hz

Rated residual operating current I△n(A): 0.03, 0.1, 0.3, 0.5

Rated residual non operating current I△no: 0.5I△n

Rated conditional short-circuit current Inc: 10kA

Rated conditional residual short-circuit Current I△c: 10kA

Residual tripping current range: 0.5I△n~I△n

Terminal Connection Height: 21mm

Electro-mechanical endurance: 4000 cycles

Connection capacity: Rigid conductor 25mm ²

Connection terminal:Screw terminal

Pillar terminal with clamp

Fastening torque: 2.0N.m

Installation:On symmetrical DIN rail 35.5mm

Panel mounting

Protection class:IP20

Construction and Feature 




Provides protection against earth fault/leakage current and function of isolation

High short-circuit current withstand capacity

Applicable to terminal and pin/fork type busbar connection

Contact position indication

Equipped with finger protected connection terminals

Fire resistant plastic parts endures abnormal heating and strong impact

Automatically disconnect the circuit when earth fault/ leakage current occurs and

exceeds the rated sensitivity.

Independent of power supply and line voltage, and free from external interference,voltage fluctuation.

Overall & Installation Dimensions

Wiring Diagram