Hot selling europe market 6-32A 1P+N CB approval AFDD untis arc fault circuit breaker

Hot selling europe market 6-32A 1P+N CB approval AFDD untis arc fault circuit breaker
Hot selling europe market 6-32A 1P+N CB approval AFDD untis arc fault circuit breakerHot selling europe market 6-32A 1P+N CB approval AFDD untis arc fault circuit breakerHot selling europe market 6-32A 1P+N CB approval AFDD untis arc fault circuit breakerHot selling europe market 6-32A 1P+N CB approval AFDD untis arc fault circuit breaker
group name
AFDD
Min Order
1 piece
model
AFDD
Delivery clauses under the trade mode
FOB, CFR, EXW
Acceptable payment methods
T/T, L/C, Credit Card, PayPal, Westem Union, Cash
update time
Tue, 15 Oct 2019 12:13:32 GMT

Paramtents

  • Pole No 1P+N

  • Rated voltage AC 230

  • Rated current(A) 6A,10A,16A, 20A,25A & 32A

  • Tripping curve B,C

  • Rated frequency 50/60Hz

  • Energy limiting class 3

  • Rated impulse withstand voltage 6.2kV

  • Fastening torque 2 0Nm

  • High short-circuit breaking capacity (Icn) 6kA

  • Electro-mechanical endurance 10000

Packging & Delivery

  • Min Order1 piece

Briefing

Connected by our DPC100 special busbar. They also can be connected by suitable cables in line with Wiring regulations BS7671.

Detailed

Technical Data

 PoleNo.: 1P+N

Rated voltage: AC 230

Rated current (A): 6A,10A,16A, 20A,25A & 32A


Tripping curve: B, C, 

High short-circuit breaking capacity (lcn):6kA

Rated frequency: 50/60Hz

Energy limiting class: 3

Rated impulse withstand voltage: 6.2kV

Electromechanical endurance: 10000

Contact position indication

Fastening torque: 2.0Nm

Connection terminal:Screw terminal Pillar terminal with clamp

Connection capacity: Rigid conductor up to 25mm2

Fastening torque: 2.0Nm

Installation:On symmetrical DIN rail 35.5 mm Panel mounting 

Terminal Connection Height: 21mm

General Information

The AFM range AFDD consists of a MCB (Miniature Circuit Breaker) and a Arc fault detection module in a 1 Pole +N, 2 module DIN rail mounted unit. They combine short circuit, overload and arc fault protection and will switch off in the event of these faults being detected.

The Arc detection unit will recognise serial, parallel and ground arc faults in both radial and ring circuits. (Note serial faults in a ring circuit does not always lead to an arc fault due to power flowing to either side of the fault at the same potential voltage.

These units must be switched off when conducting insulation testing to avoid damage to the AFDD

The AFDD should be tested every month by pushing the Test button.

 Recommended terminal screw torque 2Nm

Overall & Installation Dimensions